Integrating Passive Cooling and Solar Techniques into the Existing Building in South China | Scientific.Net

Integrating Passive Cooling and Solar Techniques into the Existing Building in South China

Article Preview

Abstract:

This paper draws upon passive cooling and passive solar techniques to integrate them into a common multi-purpose building in South China so as to optimize the indoor thermal environment and reduce building energy consumption. Meanwhile, it also discusses how to combine architecture design and sustainable techniques reasonably. In order to prove that these sustainable design options are effective, CFD, Ecotect and Solpass software should be used to simulate or calculate the heating and cooling loads, discomfort hours for both of the existing and advanced building. Though comparison it is obviously that the indoor discomfort hours decrease by nearly one third by passive cooling system, while passive solar techniques can reduce 25% annual heating loads.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 368-373)

Pages:

3717-3720

Citation:

Online since:

October 2011

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Liping,W. and Hien,W. N.: Building and Environment, Vol. 42 (2007), pp.4006-4015

Google Scholar

[2] Simon Guy and Steven A. Moore: Sustainable architectures (Spon Press, UK 2005).

Google Scholar

[3] Information on http://203.175.156.108:9922/docc/assessment.html

Google Scholar

[4] M. Macias, J.A. Gaona, J.M. Luxan and Gloria Gomez: Energy and Buildings, Vol. 41(2009), p.915–921

DOI: 10.1016/j.enbuild.2009.03.013

Google Scholar

[5] Michele Zinzi and Marco Citterio: Experience on passive cooling techniques for buildings, ASIEPI Project (2010)

Google Scholar

[6] David A. Bainbridge: A Water Wall Solar Design Manual, Available at: http://www.builditsolar.com/Projects/SpaceHeating/AWaterWallIntro.pdf (2005)

Google Scholar